{"id":3955,"date":"2016-05-30T05:28:45","date_gmt":"2016-05-30T05:28:45","guid":{"rendered":"http:\/\/kmlg.com\/mlcfl\/?page_id=3955"},"modified":"2020-03-05T18:46:18","modified_gmt":"2020-03-05T18:46:18","slug":"white-cement","status":"publish","type":"page","link":"https:\/\/www.kmlg.com\/mlcfl\/white-cement\/","title":{"rendered":"White Cement"},"content":{"rendered":"<p>[vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text el_class=&#8221;title-cls&#8221;]<\/p>\n<h2>White Cement<\/h2>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;30px&#8221;][vc_column_text el_class=&#8221;title-cls&#8221;]White Cement is identical to Grey Portland Cement except in colour. White Portland<br \/>\nCement is used in combination with white aggregates to produce white concrete for<br \/>\nprestige construction projects and decorative work. White concrete usually takes the<br \/>\nform of precast cladding panels, since it is not economical to use White Cement for<br \/>\nstructural purposes.[\/vc_column_text][vc_empty_space height=&#8221;30px&#8221;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;5986&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; vc_none_hover_effect=&#8221;&#8221; css=&#8221;.vc_custom_1583433975864{margin-top: -30px !important;}&#8221;][vc_empty_space height=&#8221;30px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_toggle title=&#8221;Specifications&#8221; el_id=&#8221;white-cement&#8221; el_class=&#8221;toggle-cls&#8221;]<\/p>\n<div class=\"col-md-12 mb-40\">\n<div class=\"table-responsive\">\n<h6 style=\"text-align: center;\">Physical Specifications<\/h6>\n<table class=\"table\">\n<thead>\n<tr>\n<th>Characteristic<\/th>\n<th>Unit<\/th>\n<th>IS (8042\u00a0: 1989)<\/th>\n<th>PS (1630\u00a0: 1984)<\/th>\n<th>MS (888\u00a0: 1991)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Fineness<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Blaine<\/td>\n<td>Cm2\/g<\/td>\n<td>2250 Min<\/td>\n<td>\u00a02250 Min<\/td>\n<td>\u00a0NR<\/td>\n<\/tr>\n<tr>\n<td><strong>Soundness<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Le-Chatelier Method<\/td>\n<td>mm<\/td>\n<td>10 Max<\/td>\n<td>\u00a010 Max<\/td>\n<td>\u00a010 Max<\/td>\n<\/tr>\n<tr>\n<td><strong>Setting Time<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Initial<br \/>\nFinal<\/td>\n<td>Minutes<br \/>\nMinutes<\/td>\n<td>45 Min.<br \/>\n600 Max<\/td>\n<td>45 Min.<br \/>\n600 Max<\/td>\n<td>60 Min.<br \/>\nNR<\/td>\n<\/tr>\n<tr>\n<td><strong>Compressive Strength<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>2 Days<\/td>\n<td>(Mpa)<\/td>\n<td>NR<\/td>\n<td>NR<\/td>\n<td>10.0 Min<\/td>\n<\/tr>\n<tr>\n<td>3 Days<\/td>\n<td>(Mpa)<\/td>\n<td>14.4 Min<\/td>\n<td>12.0 Min<\/td>\n<td>NR<\/td>\n<\/tr>\n<tr>\n<td>7 Days<\/td>\n<td>(Mpa)<\/td>\n<td>19.8 Min<\/td>\n<td>19.0 Min<\/td>\n<td>NR<\/td>\n<\/tr>\n<tr>\n<td>28 Days<\/td>\n<td>(Mpa)<\/td>\n<td>29.7 Min<\/td>\n<td>NR<\/td>\n<td>42.5\u00a0Min<\/td>\n<\/tr>\n<tr>\n<td><strong>Whiteness<\/strong><\/td>\n<td>\u00a0%<\/td>\n<td>\u00a070 Min<\/td>\n<td>\u00a070 Min<\/td>\n<td>\u00a080 Min<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"col-md-12 mb-40\">\n<div class=\"table-responsive\">\n<h6 style=\"text-align: center;\">Chemical Specifications<\/h6>\n<table class=\"table\">\n<thead>\n<tr>\n<th>Characteristic<\/th>\n<th>Unit<\/th>\n<th>IS (8042\u00a0: 1989)<\/th>\n<th>PS (1630\u00a0: 1984)<\/th>\n<th>MS (888\u00a0: 1991)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Lime Saturation Factor<\/td>\n<td>\u00a0Ratio<\/td>\n<td>\u00a00.66 &#8211; 1.02<\/td>\n<td>\u00a00.66 -1.02<\/td>\n<td>\u00a0NR<\/td>\n<\/tr>\n<tr>\n<td>Insoluble Residue<\/td>\n<td>%<\/td>\n<td>2.00 Max.<\/td>\n<td>\u00a01.50 Max.<\/td>\n<td>\u00a05.00 Max.<\/td>\n<\/tr>\n<tr>\n<td>Iron Oxide<\/td>\n<td>%<\/td>\n<td>\u00a01.00 Max.<\/td>\n<td>\u00a01.00 Max.<\/td>\n<td>\u00a00.5\u00a0Max.<\/td>\n<\/tr>\n<tr>\n<td>Magnesia<\/td>\n<td>%<\/td>\n<td>6.00 Max.<\/td>\n<td>\u00a04.00 Max.<\/td>\n<td>5.0 Max.(For Clinker)<\/td>\n<\/tr>\n<tr>\n<td>Sulphuric Anhydride<\/td>\n<td>%<\/td>\n<td>\u00a03.00 Max.<\/td>\n<td>\u00a03.00 Max.<\/td>\n<td>\u00a03.00 Max.<\/td>\n<\/tr>\n<tr>\n<td>Loss on Ignition<\/td>\n<td>%<\/td>\n<td>NR<\/td>\n<td>\u00a0NR<\/td>\n<td>\u00a05.00 Max.<\/td>\n<\/tr>\n<tr>\n<td>Total Chlorides<\/td>\n<td>%<\/td>\n<td>NR<\/td>\n<td>\u00a0NR<\/td>\n<td>\u00a00.10 Max<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>[\/vc_toggle][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;30px&#8221;][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text el_class=&#8221;title-cls&#8221;] White Cement [\/vc_column_text][vc_empty_space height=&#8221;30px&#8221;][vc_column_text el_class=&#8221;title-cls&#8221;]White Cement is identical to Grey Portland Cement except in colour. White Portland Cement is used in combination<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.kmlg.com\/mlcfl\/wp-json\/wp\/v2\/pages\/3955"}],"collection":[{"href":"https:\/\/www.kmlg.com\/mlcfl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.kmlg.com\/mlcfl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmlg.com\/mlcfl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmlg.com\/mlcfl\/wp-json\/wp\/v2\/comments?post=3955"}],"version-history":[{"count":10,"href":"https:\/\/www.kmlg.com\/mlcfl\/wp-json\/wp\/v2\/pages\/3955\/revisions"}],"predecessor-version":[{"id":6034,"href":"https:\/\/www.kmlg.com\/mlcfl\/wp-json\/wp\/v2\/pages\/3955\/revisions\/6034"}],"wp:attachment":[{"href":"https:\/\/www.kmlg.com\/mlcfl\/wp-json\/wp\/v2\/media?parent=3955"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}